EURECA-Logo
ImprintContactGeneral Trading Terms
Optoelectronic Optics/Filters Cooling
zur deutschsprachigen Seite zur englischsprachigen Seite

KRYOTHERM -
Generating Thermoelectric Modules

generating thermoelectric module by KRYOTHERM

Nations the world over are actively searching for alternative, clean energy sources. Using the thermoelectric modules to generate electro energy is becoming vital, valid choice. Interest in energy sources such as thermoelectric generating modules is warming because of the latest achievements in the sphere of thermoelectric technology and constructions.

Using the generating thermoelectric modules (TGM), produced by KRYOTHERM, makes it possible to provide generation of the electro energy with up to 10 W with direct current voltage up to 6 V with one TGM with a temperature difference of 100 °С.




Chilling Units
Thermoelectric Peltier Elements
Thermoelectric Seebeck Generators
Eureca
Kryotherm
Heat Conductive and Insulating Products
Heatsinks/Heatexchanger
Fans
Power Supplies
Service
Exhibitions



Main TGM application:

  • utilization of worthless heat at transport installations (automobiles, ships);
  • autonomic supply of energy to electronic blocks for water boilers and disposal plants;
  • cathodic protection of the oil and gas pipelines;
  • conversion of natural heat resources — geothermal waters, etc into electric energy;
  • autonomic power supply of low-power electric devices.

Application recommendations:

  1. Generating modules (TGM) must be installed on flat surface. This requirement is especially vital for the cold side of TGM. The purity of surface processing on which TGM is installed must be better than 20 microns.
  2. The pressing force must be not less than 12-15 kg/cm2
  3. Temperature of the hot seam shall not exceed 200 °C

Attention! During the exploitation of TGM with the decrease of electric load an increase of the hot seam temperature up to 5% off the difference between hot and cold sides of the module can follow.


Type Geometrical Dimensions, mm Cold end = 50 0C Hot end = 150 0C Small
Volumes
on Stock
Internal Resistance Heat Resistance Voltage Current Power Efficiency
A B H Ohm K/W V A W %
TGM-127-1.0-0.8 30 30 3.1 2.41 1.40 1.83 0.76 1.38 2.3
TGM-127-1.0-1.3 30 30 3.6 3.92 2.27 2.18 0.56 1.21 2.7
TGM-127-1.0-2.5 30 30 4.3 7.53 4.36 2.55 0.34 0.86 3.2
TGM-127-1.4-1.5 40 40 3.9 2.46 1.43 2.25 0.91 2.05 2.8
TGM-127-1.4-2.5 40 40 4.8 3.84 2.23 2.50 0.65 1.63 3.2
TGM-199-1.4-0.8 40 40 3.2 1.93 0.45 2.19 1.14 2.49 1.8
TGM-199-1.4-1.2 40 40 3.6 2.89 0.68 2.69 0.93 2.50 2.2
TGM-199-1.4-1.5 40 40 3.9 3.85 0.91 3.03 0.79 2.39 2.4
TGM-287-1.0-1.3 40 40 3.6 8.85 1.00 4.54 0.51 2.33 2.5
TGM-287-1.0-1.5 40 40 3.8 10.20 1.16 4.77 0.47 2.23 2.7 Häkchen
TGM-287-1.0-2.5 40 40 4.8 17.00 1.93 5.49 0.32 1.77 3.1 Häkchen